STACK VENTILATION SOLUTIONS FOR HOMES IN THE TROPICAL CITY OF JAKARTA: CASE STUDY OF A HOUSE AT NORTH JAKARTA
Main Article Content
Abstract
The growing problem of urbanization has led to the expansion of densely populated cities such as Jakarta, resulting in issues including limited green spaces, elevated vehicle pollution, and industrial pollution. Tropical climates with high temperatures and humidity require indoor thermal comfort maintenance, especially due to climate change. An approach to achieving thermal comfort in tropical regions is the use of natural ventilation, such as stack ventilation. This stack ventilation will increase airflow, improve thermal comfort, and reduce electricity use by reducing reliance on air conditioning. Stack ventilation does not require a prevailing wind around the dwelling, as it relies on the upward air movement driven by buoyancy forces. Stack ventilation, being independent of outdoor wind speeds, can also mitigate the pollutants carried by outdoor wind currents, thereby improving indoor air quality and creating a healthier living environment. This study used an exploratory empirical case study approach to study a residence that has effectively utilized stack ventilation and achieved awards for its energy conservation initiatives. Stack ventilation can be effectively utilized in dwellings with a void and in near-isothermal tropical conditions by integrating an induced-solar-heat glass chamber at the apex of the solar chimney. This configuration creates a heated zone that facilitates the ascent of less dense air, which is then expelled from the top of the shaft. This study's findings are a preliminary insight for the implementation of stack ventilation in residential properties. Stack ventilation is suggested for residential homes in densely populated cities like Jakarta, effectively utilizing voids to facilitate the system with an induced solar-heat chimney.
Article Details

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
References
Acred, A., & Hunt, G. R. (2016). Multiple Flow Regimes in Stack Ventilation of Multi-Storey Atrium Buildings. 3315(June). https://doi.org/10.1080/14733315.2013.11684000
Aulia, S. A. (2024). Air pollution threatens health and climate change in Jakarta. 1(1), 1–10.
Bramiana, C. N., Mahjuddin, A., Aminuddin, R., & Azzam, M. (2022). Investigating natural ventilation performance on apartment units in Jakarta based on field test measurements. 22(3), 140–186.
Jarzabska, R., Pawłowski, K., & Niedostatkiewicz, M. (2021). Improvement of the Chimney Effect in Stack Ventilation. Applied Sciences.
Miyamoto, K., Pratiwi, S. N., Nishiiri, S., Takaguchi, H., & Kubota, T. (2024). Relationship between Cooling Methods and Energy Consumption for the Development of Low-Carbon Collective Housing in Indonesia. 16(4), 1–17.
Moey, L. K., Sing, Y. H., Tai, V. C., Go, T. F., & Yoong, Y. (2021). Effect of Opening Size on Wind-Driven Cross Ventilation. 6, 99–108.
Mostofa, T., Manteghi, G., & Lamit, H. (2019). Stack Ventilation as A Design Tool to Improve Indoor Thermal Comfort of Duplex Studio at Soho High Rise in Hot and Humid Climate. 1(1), 144–153.
Mufida, E. (2021). Potential of Sloped Solar Chimney for the Architectural Development of Sustainable Applied Technology Models for Passive Air Ventilation. 21(April), 13–20.
Nguyen, Y. Q., Nguyen, V. T., Tran, L. T., & Wells, J. C. (2022). CFD Analysis of Different Ventilation Strategies for a Room with a Heated Wall.
Nugroho, A. M. (2016). Solar Chimney Geometry for Stack Ventilation in a Warm Humid Climate. 3315(September). https://doi.org/10.1080/14733315.2006.11683841
Owen, Mark. S. (Ed.). (2009). 2009 ASHRAE Handbook: Fundamentals. American Society of Heating, Refrigeration and Air-Conditioning Engineers.
Rezadoost, R., Bazazzadeh, H., & Taban, M. (2023). Optimizing stack ventilation in low and medium-rise residential buildings in hot and semi-humid climate. Case Studies in Thermal Engineering, 52(March), 103555. https://doi.org/10.1016/j.csite.2023.103555
Siti, N., Nik, F., Misni, A., Nor, S., & Buyadi, A. (2023). Investigation of Thermal Comfort for A Naturally Ventilated House : Correlation between Climatic Design Strategy and Thermal Data Analysis. 5, 170–184.
Suwarman, R., Riawan, E., Sahat, Y., Simanjuntak, M., & Irawan, D. E. (2022). Kajian Perubahan Iklim di Pesisir Jakarta Berdasarkan Data Curah Hujan dan Temperatur. 11(1), 99–110. https://doi.org/10.14710/buloma.v11i1.42749
Wahab, I. A., Athirah, N., Bakar, A., & Mohd, M. J. (2023). VENTILATION SHAFT DESIGN IN ENHANCING INDOOR AIR MOVEMENT FOR PUBLIC BUILDING. 4(1), 25–28.
Wahab, I. A., Ismail, L. H., & Kadir, A. A. (2016). Opening Design and Position Effect on Building Natural Stack Effect and Cross Ventilation. 0869(1), 13–22.
Zhang, H., Tao, Y., & Shi, L. (2021). Solar Chimney Applications in Buildings. 409–422.